Development and validation of an LC-MS/MS method for detection and quantification of in vivo derived metabolites of [Pyr1]apelin-13 in humans

Publication: Nature

Duuamene Nyimanu, Richard G. Kay, Petra Sulentic, Rhoda E. Kuc, Philip Ambery, Lutz Jermutus, Frank Reimann, Fiona M. Gribble, Joseph Cheriyan, Janet J. Maguire, Anthony P. Davenport

27 December 2019

________________________________________________________________

Summary:

An LC-MS method was developed to measure Apelin in human plasma, and demonstrate apelin dosing achieved the correct concentration in volunteers. The extracts were also analysed on an LC-MS system to identify break-down products of the peptide that were produced in the body. The researchers found out that apelin is broken down from both ends of the peptide, but more so from the C-terminal. This information can be used to develop a better peptide that is stabilised against degradation, therefore improving its characteristics as a drug; and apelin-derived peptides may be potential new drugs for cardiovascular disease.

View publication